Increased safety and unique flexibility
It is a new concept of endopile designed to dramatically reduce tip fracture without reducing the cutting force and to facilitate removal of the fractured part as fracture occurs at the spring part located outside the root canal even if fracture occurs.
Spring Endo File Video
Spring Endo File Safety Flexibility Cutting Force Increased Durability Spring Endo File Safety Flexibility Cutting Force Increased Durability Spring Endo File Safety Flexibility Cutting Force Increased Durability Spring Endo File Safety Flexibility Cutting Force Increased Durability Spring Endo File Safety Flexibility Cutting Force Increased Durability Spring Endo File Safety Flexibility Cutting Force Increased Durability
Problems of existing products
Often a situation where the tip is broken and gets stuck in the root canal
If the “fracture occurs at the tip”, more than 95% of the cases, the failure to remove the fragment may increase the likelihood of a medical dispute. Existing products without a spring structure often fracture the tip of the cutting edge at the apical end during root canal treatment, and it is often difficult to remove it.It is not easy to prevent tip fracture as the operator cannot detect that the cutting edge is overloaded. In patients with poor mouth opening, both the patient and the surgeon have a hard time treating the posterior teeth. Due to the straightness of the file, a large amount of tooth removal is required. Since there is no structure to buffer the overload applied to the cutting edge, the possibility of tip fracture during repeated reuse increases significantly.
Advantages
Increased safety
Spring structure buffers overload on file
Exisiting Endo File
Denflex Spring Endo File
Unique Flexibility
Even with the spring part bent(60-70 degree), it is able to send 100% rotational power
It is useful for the posterior part of patients who cannot open their mouth wide.
Even if the root canal is bent away from the central axis of the tooth, excessive tooth removal is not necessary.
Exisiting Endo File
Denflex Spring Endo File
Optimized for a curved root canal
Cutting Force
Micro-vibration of the spring increases the cutting power.
It improves cutting power by generating micro-vibration.
Due to the micro-vibration, the screw-in phenomenon into the canal of the blade area is significantly reduced
Increased durability
Our Spring Endo File has increased the number of uses compared to general Endo files, and shows improved results compared to general files in Cyclic Fatigue Resistance Test.
Group | Cyclic Fatigue Resistance / NCF |
---|---|
Spring File #25 | 1841 ± 489 |
Non-Spring File #25 | 1450 ± 386 |
Division | Probability of breaking tip |
---|---|
Existing Endo File | 100% |
Spring Endo File | 40% |
SPECIFICATION
Product Information
Spring Endo File Hi Plus (Bendable)
ISO Size | 23MM | 25MM |
---|---|---|
10 |
DFSEF-B-L2310A2-CW(CR)
|
DFSEF-B-L2510A2-CW(CR)
|
15 |
DFSEF-B-L2315A4-CW(CR)
|
DFSEF-B-L2515A4-CW(CR)
|
20 |
DFSEF-B-L2320A6-CW(CR)
|
DFSEF-B-L2520A6-CW(CR)
|
25 |
DFSEF-B-L2325A4-CW(CR)
DFSEF-B-L2325A6-CW(CR) |
DFSEF-B-L2525A4-CW(CR)
DFSEF-B-L2525A6-CW(CR) |
30 |
DFSEF-B-L2330A4-CW(CR)
DFSEF-B-L2330A6-CW(CR) |
DFSEF-B-L2530A4-CW(CR)
DFSEF-B-L2530A6-CW(CR) |
40 |
DFSEF-B-L2540A5-CW(CR)
|
|
50 |
DFSEF-B-L2550A5-CW(CR)
|
Spring Endo File (Standard)
ISO Size | 23MM | 25MM |
---|---|---|
PATH |
DFSEF-P-L2300-SD
|
DFSEF-P-L2500-SD
|
10 |
DFSEF-S-L2310A2-CW(CR)
|
DFSEF-S-L2510A2-CW(CR)
|
15 |
DFSEF-S-L2315A4-CW(CR)
|
DFSEF-S-L2515A4-CW(CR)
|
20 |
DFSEF-S-L2320A6-CW(CR)
|
DFSEF-S-L2520A6-CW(CR)
|
25 |
DFSEF-S-L2325A4-CW(CR)
DFSEF-S-L2325A6-CW(CR) |
DFSEF-S-L2525A4-CW(CR)
DFSEF-S-L2525A6-CW(CR) |
30 |
DFSEF-S-L2330A4-CW(CR)
DFSEF-S-L2330A6-CW(CR) |
DFSEF-S-L2530A4-CW(CR)
DFSEF-S-L2530A6-CW(CR) |
40 |
DFSEF-S-L2540A5-CW(CR)
|
|
50 |
DFSEF-S-L2550A5-CW(CR)
|